SH4 / Partner J Connection Details
This was put together to assist in connecting all the equipment together - and making it work the way it's supposed to.
This tutorial follows the same steps as outlined in Introductory Lab 1.
The Equipment
To have a fully operational SH4 we need the following equipment
| Motherboard with SH4 daughterboard | |
| 300W ATX power supply PartnerJ power supply |
|
| PartnerJ box | |
| Cables - Standard power cable for ATX supply - JTag Cable for PartnerJ - LPT Cable for PartnerJ |
Position the equipment
First things first - place the motherboard w/ SH4 board, ATX power supply
and the Partner J on a desk/table.

Connect LPT to PartnerJ and to computer (ref picture of
cables)
When connecting the JTag cable to the PartnerJ be careful - the small
circuit board at the end of the cable is fragile...
Connect PartnerJ JTAG Cable to SH4 Board (see below).
Connect the other end of the JTag cable to the connection marked "JTag Cable
Input" below. You should hear a slight click when it's in place.
Leave the Reset Probe disconnected for now.

Connect the power supply to the PartnerJ and make sure it turns on (power LED)
Connect the output power cable from the ATX power supply to the ATX Power
Connector on the motherboard.
See figure. Make sure the clip on the
connector snaps in place.
DO NOT POWER UP THE ATX SUPPLY YET!
Attach the Reset Probe to the SH4 board (can be tricky)
Locate pin labeled RESET2 on the top of the SH4 board (3rd pin in a row of 3
pins next to LED)
When you attach it, make sure to press down on the top so the metal
conductors come out all the way

Make sure your setup looks something like below

Finally, connect the ATX power supply to an outlet and turn it on.
A small red LED close to the ATX Power connector should come on. Once the
LED is on, press the power button on the motherboard. This is a small button
located at the bottom of the motherboard, to the immediate left of the battery.
It is visible on the bottom of the above picture. The button is labeled SW6
PWR.
If LED's illuminate and the seven segment counters turn on - everything should be set.
NOTE --- If one of the two LED's next to the power button on the motherboard is
flashing, the reset probe is not attached properly. Turn off the board, and
reattach the probe.